Hardware and Software Installation
Rev 2.0 Mar.10 43
Step 5- Start ACEmanager
ACEmanager is a free utility. Follow the steps below to connect to ACEmanager.
• Ensure MP connectivity to access ACEmanager.
• Go to: http://192.168.13.31:9191 the first time you connect to ACEmanager.
• Enter username as User and password as 12345.
• By default ethernet uses public mode and all other interfaces are in private
mode using different subnets to differentiate the connection types.
The default private for Ethernet is also in a different subnet from the other
connection types.
*can be changed via ACEmanager
Table 2-1: Factory Defaults
Interface MP Connected Device
Ethernet Private default 192.168.13.31* 192.168.15.100
USB/NET 192.168.14.31 192.168.14.100
DUN 192.168.15.31 192.168.15.100
WiFi* 192.168.17.31 192.168.17.100