Table 2-2: GX400 Digital I/O Specifications
Pin Name Specification Param Min Typ Max Units
4 Dig I/O
(Input)
Input low state
voltage
VIL -0.5 0 1.2 V
Input high state
voltage range
VIH 1.3 3.3 30 V
Input leakage current
(3.3 VDC IN)
IIN ---- 58 ---- μA
Typical application input source is a dry switch contact to ground.
Pin includes an internal 56K ohm pull up to 3.3 VDC.
Dig I/O
(Output)
Open drain drive to
ground
Idc ---- 150 200 mA
Maximum open
circuit voltage
applied
Voc ---- 3.3 30 V
Typical application is to drive a relay coil to ground.