Rev 2.0 Feb.12 41
5
5: Inputs, Relay Outputs, and Power Status
Capturing External
Events
Power Modes and
Information
The AirLink GX400 can be configured to monitor the input, respond
to specific types of events, and trigger digital output. The device can
also be configured to change its power mode in order to conserve
power. These features can be configured to your needs.
Capturing External Events
The AirLink GX400 is equipped with an I/O port interface which
includes one low power timer enable input and one digital I/O. These
may be connected to sensors and switches to monitor status and
remotely control equipment.
AirLink GX400 board supports a low power timer enable input pin
and a digital I/O pin which are connected to the CPU processor. The
I/O signal comes in from the power connector, through a PolySwitch
resettable fuse, and ties into the CPU pins with protection circuitry.
Digital Input
Digital Input can be used in two different modes: the switch mode or
the voltage sensing mode.
Figure 5-1: Digital Input Contact Closure
The switch mode senses contact closures. The digital input can
report either an open or closed state, and can be wired to a ground
signal via a switch. When the switch is open, the input reads “3.3V”.
When the switch is closed, the input reads “OV”.
Digital I/O
Ground
Contact
Digital Input