WA_DEV_W228_UGD_002 Rev 003 Page 11 of 78
WISMO228 TCP/IP AT Commands
Manual
2. Principles
The AT+WIP AT Commands implements the TCP/IP protocols using custom AT commands. The
commands are sent from an external application and the corresponding responses are sent back from
the WISMO
®
to the external application.
AT+WIP commands involve:
a host computer, which issues the AT+WIP commands
®
the rest of the Internet/Intranet
Multiplexing: Several sockets can be operating at once. The +WIPDATA command allows the
temporary identification of the UART in data mode with a given socket. The data written on the
UART is transferred through the socket. The data which arrives on the socket can be read from the
UART.
In AT mode, the host receives an unsolicited event when the data arrives on the socket.
Sockets Identification
Sockets are identified by a pair of numbers: the first one identifies the protocol; the second one
identifies a given socket of the protocol.