WA_DEV_W228_UGD_002 Rev 003 Page 25 of 78
WISMO228 TCP/IP AT Commands
Manual
Parameter Storage
Several bearer configuration sets can be saved.
Calling AT+WIPBR=6,<bid>,1 twice with the same <bid> will store the last configuration set.

with the bearer <bid> into non-volatile memory.

with the bearer <bid>.

existing.
Possible Errors


+CM EE AT error code
Description
800
invalid option
801
invalid option value
802
not enough memory left
803
operation not allowed in the current WIP stack state
804
device already open
807
bearer connection failure : line busy
808
bearer connection failure : no answer
814
bearer connection failure : PPP authentication failed
815
bearer connection failure : PPP IPCP negotiation failed
820
error writing configuration in non-volatile memory
821
error freeing configuration in non-volatile memory
847
bearer connection failure: WIP_BOPT_GPRS_TIMEOUT time limit expired
before GPRS bearer connected
848
impossible to connect to the bearer
849
connection to the bearer has succeeded but a problem has occurred during
the data flow establishment