WA_DEV_W228_UGD_002 Rev 003 Page 37 of 78
WISMO228 TCP/IP AT Commands
Manual
command.
Parameter Storage
None
Possible Errors
The possible error message is displayed only if 

+CM EE AT error code
Description
802
not enough memory
803
operation not allowed in the current TCP/IP stack state
830
bad index
831
bad state
834
not implemented
837
bad protocol
Examples
Command
Responses
AT+WIPCLOSE=1,1
Note: Close UDP socket with communication index 1
OK
AT+WIPCLOSE=2,1
Note: Close TCP client with communication index 1
OK
AT+WIPCLOSE=3,1
Note: Close TCP server with communication index 1
OK
Notes
After issuing the +WIPCLOSE command, no more data can be sent and received over the socket.